Shaw Pipe Logo
Search
center tabAbout Shaw PipeRecent NewsSitemapExtranet Login for CustomersContact Us

Home » Concrete Pipe » Typical Pipe Joint Dimensions

Typical Pipe Joint Dimensions

arrow  300mm, 375mm, 450mm, 525mm, 600mm, & 750mm diameter pipe

300mm-750mm Diameter Pipe
rule pipe

arrow  900mm, 1050mm, 1200mm, 1500mm (B Wall), 1500mm (C Wall),
 2100mm, & 2400mm (C Wall)

300mm-750mm Diameter Pipe
rule pipe

arrow  1350mm, 1500mm 140D (C Wall ), 1800mm, 2100mm MONO,
 2400mm (B Wall), & 2400mm MONO diameter pipe

C-Wall 2400mm
rule pipe

arrow  3000mm Diameter Pipe

300mm-750mm Diameter Pipe

Pipe size
  Prod.
Wall
                                 
mm
in.
Type
Type
I.D.
O.D.
WT
A
B
C
D
E
F
G
H
J
K
L
M
N
Gasket
300
12
P3
B
304.80
406.40
50.80
88.90
41.38
55.46
165.10
126.49
46.04
34.65
114.30
44.45
44.45
5.08
6.31
16.15
TSS
375
15
P3
B
381.00
495.30
57.15
88.90
47.10
56.08
165.10
143.93
52.39
40.37
114.30
44.45
44.45
5.08
6.93
16.78
TSS
450
18
P3
B
457.20
584.20
63.50
88.90
47.10
62.43
165.10
125.11
45.54
40.37
114.30
44.45
44.45
5.08
13.28
23.13
TSS
525
21
P3
B
533.40
673.10
69.85
88.90
47.10
62.43
177.80
109.04
39.69
40.37
114.30
44.45
44.45
5.08
19.63
29.48
TSS
600
24
P3
B
609.60
762.00
76.20
88.90
47.10
62.43
177.80
91.59
33.34
40.37
114.30
44.45
44.45
5.08
25.98
35.83
TSS
750
30
P3
B
762.00
939.80
88.90
88.90
50.80
69.85
177.80
87.23
31.75
44.07
114.30
44.45
44.45
5.08
34.99
44.83
TSS
900
36
P3
C
914.40
1155.70
120.65
88.90
50.80
69.85
N/A
N/A
N/A
44.07
114.30
44.45
44.45
5.08
66.74
76.53
TSS
1050
42
P3
B
1066.80
1295.40
114.30
107.95
52.54
61.76
N/A
N/A
N/A
43.43
133.35
63.50
44.45
7.62
58.48
70.87
TSS
1200
48
P3
B
1219.20
1473.20
127.00
107.95
62.06
64.94
N/A
N/A
N/A
52.96
133.35
63.50
44.45
7.62
61.66
74.04
TSS
1350
54
VUP
B
1371.60
1651.00
139.70
108.00
58.40
81.30
N/A
N/A
N/A
56.10
105.70
N/A
N/A
N/A
N/A
83.60
ORING
1500
60
P3
B
1524.00
1828.80
152.40
120.65
64.72
87.68
N/A
N/A
N/A
53.39
146.05
63.50
57.15
0.30
86.63
99.01
TSS
1500
60
WC
C
1524.00
1866.90
171.45
120.65
71.07
100.38
N/A
N/A
N/A
70.62
120.65
63.50
57.15
0.30
N/A
100.83
TSS
1500 140D
60
VUP
C
1524.00
1866.90
171.45
120.65
64.72
106.73
N/A
N/A
N/A
62.46
120.65
N/A
N/A
N/A
N/A
108.99
ORING
1800
72
VUP
C
1828.80
2222.50
196.85
133.35
92.08
104.77
N/A
N/A
N/A
89.71
133.35
N/A
N/A
N/A
N/A
107.14
ORING
2100
84
VUP
C
2133.60
2578.10
222.25
127.00
87.31
134.94
N/A
N/A
N/A
76.42
127.00
69.85
127.00
0.35
N/A
145.83
TSS
2400
96
VUP
B
2438.40
2895.60
228.60
127.00
101.22
148.87
N/A
N/A
N/A
77.34
127.00
N/A
N/A
N/A
N/A
151.26
ORING
2400
96
WC
C
2438.40
2933.70
247.65
127.00
101.22
146.43
N/A
N/A
N/A
90.96
127.00
69.85
57.15
8.99
N/A
156.69
TSS
3000
120
WC
C
3048.00
3657.60
304.80
152.40
110.76
194.04
N/A
N/A
N/A
100.50
152.40
69.85
N/A
8.99
N/A
204.30
TSS

NOTE: Properly specified and inspected pipe, correct laying and jointing procedures, careful bedding, backfilling, and compaction all contribute to a satisfactorily installed, testable sanitary pipeline. SHAW PIPE recommends that for sanitary pipe installations, good practice dictates that the first 100 meters of pipe installed by each crew should be immediately tested and not more than 300 meters of pipeline per crew should be untested at any time.

Download Typical Pipe Joint Dimensions Table

rule pipe
arrow2 Typical_Pipe_Joint_Dimensions.pdf (212 KB) pdf icon

Powered By: ssCMS 2.2.0.0