Shaw Pipe Logo
Search
center tabAbout Shaw PipeRecent NewsSitemapExtranet Login for CustomersContact Us

Home » Manholes & Catchbasins » Manholes » 1500mm-3000mm

1500mm-3000mm


BULLET TYPICAL 1500mm-3000mm DIAMETER
FLAT TOP MANHOLE

arrow  LARGE DIAMETER MANHOLES

Manhole 1500mm-3000mm

BULLET TYPICAL 1500mm-3000mm DIAMETER
TRANSITION MANHOLE

arrow  LARGE DIAMETER MANHOLES

Manhole 1500mm-3000mm

Typical Pre-Benched Base

Walls and bottom cast as single unit. Factory benching placed to suit pipe size and location. (Some sizes may require bottom to be cast in a second pour). Base sections can be manufactured in heights ranging from 500mm to 2550mm. Refer to Diameter Selection Detail for maximum pipe sizes.

Manhole
Diameter
Wall Thickness
Base
Height
Weight
Size
mm
kg
Section
mm
kg*
1500mm
1524
171
KPB 1000
1000
2395
KPB 1250
1250
2766
KPB 1500
1500
3139
KPB 1750
1750
3511
KPB 2000
2000
3883
KPB 2250
2250
4255
KPB 2500
2500
4627
1800mm
1829
197
LPB 1000
1000
4268
LPB 1250
1250
5018
LPB 1500
1500
5768
LPB 1750
1750
6518
LPB 2000
2000
7268
LPB 2250
2250
8018
LPB 2500
2500
8768
2100mm
2134
222
**RPB 500
500
4986
RPB 1000
1000
5684
RPB 1250
1250
6694
RPB 1500
1500
7704
RPB 1750
1750
8714
RPB 2000
2000
9724
RPB 2250
2250
10734
RPB 2500
2500
11744
2400mm
2438
248
**QPB 500
500
4941
QPB 1000
1000
7246
QPB 1250
1250
8497
QPB 1500
1500
9794
QPB 1750
1750
10456
QPB 2000
2000
11481
QPB 2250
2250
12506
QPB 2550
2550
14737
3000mm
3048
305
***TPB 300
300
7700
TPB 1000
1000
7943
TPB 1500
1500
11115
TPB 2000
2000
14287
TPB 2440
2440
17079
* Approximate weights based on bottom only bases
  (benching volume varies as per requirement, pipe size, etc).
**RPB 500 & QPB 500 Bases are "Mono" style and are fabricated c/w benching.
*** 3000mm bases are fabricated with a separate base slab. See Lift Station section for detail.



BULLET TYPICAL DETAILS FOR LARGE DIAMETER
INTERMEDIATE AND REDUCING SECTIONS

arrow  TYPICAL REDUCING SECTION

Manhole 1500mm-3000mm
rule pipe

arrow  TYPICAL INTERMEDIATE LANDING SECTION

Manhole 1500mm-3000mm
rule pipe

arrow  TYPICAL INTERMEDIATE SECTION

Manhole 1500mm-3000mm

rule pipe

Typical Intermediate Sections Large Diameter Manholes

Intermediate sections are available with in-wall A-LOK gaskets or rough cut hole connections. Refer to the Manhole Diameter Selection detail for the pipe size criteria.

1500mm DIA. INTERMEDIATE SECTIONS
Inside Diameter: 1524mm
Wall Thickness: 152mm
Intermediate
*Laid Height
Weight
Section
mm
kg
KI 500
500
964
KI 750
750
1445
KI 1000
1000
1927
KI 1250
1250
2409
KI 1500
1500
2891
KI 1750
1750
3373
KI 2000
2000
3855
KI 2250
2250
4337
KI 2500
2500
4818

1800mm DIA. INTERMEDIATE SECTIONS
Inside Diameter: 1829mm
Wall Thickness: 197mm
Intermediate
*Laid Height
Weight
Section
mm
kg
LI 500
500
1348
LI 750
750
2021
LI 1000
1000
2695
LI 1250
1250
3369
LI 1500
1500
4043
LI 1750
1750
4717
LI 2000
2000
5391
LI 2250
2250
6065
LI 2500
2500
6738

2100mm DIA. INTERMEDIATE SECTIONS
Inside Diameter: 2134mm
Wall Thickness: 222mm
Intermediate
*Laid Height
Weight
Section
mm
kg
RI 750
750
2969
RI 1000
1000
3959
RI 1250
1250
4948
RI 1500
1500
5938
RI 1750
1750
6928
RI 2000
2000
7918
RI 2250
2250
8908
RI 2500
2500
9896

2400mm DIA. INTERMEDIATE SECTIONS
Inside Diameter: 2438mm
Wall Thickness: 248mm
Intermediate
*Laid Height
Weight
Section
mm
kg
QI 750
750
3449
QI 1000
1000
4599
QI 1250
1250
5748
QI 1500
1500
6898
QI 1750
1750
8048
QI 2000
2000
9198
QI 2250
2250
10348
QI 2440
2440
11726

3000mm DIA. INTERMEDIATE SECTIONS
Inside Diameter: 3048mm
Wall Thickness: 305mm
Intermediate
*Laid Height
Weight
Section
mm
kg
TI 750
750
6400
TI 1000
1000
8500
TI 1250
1250
10600
TI 1500
1500
12800
TI 1750
1750
14900
TI 2000
2000
17100
TI 2250
2250
19200
TI 2440
2440
20500


BULLET LARGE DIAMETER FLAT TOP COVERS
LARGE DIAMETER MANHOLES

arrow  (K,L,R,Q) GC 200 TGC 300

arrow  (K,L,R,Q) PC 200 TPC 300

Manhole 1500mm-3000mm Manhole 1500mm-3000mm
rule pipe

arrow  (K,L,R,Q,T) HC 300

 
Manhole 1500mm-3000mm  


BULLET Typical Flat Top Covers Large Diameter Manholes

Flat top covers are also available as intermediate landing or reducing sections. All covers produced with the standard access opening as shown. Other configurations available upon request.

1500mm DIAMETER
Flat Top
Cover Thickness
Weight
Cover
mm
kg
KGC 200
200
1314
KHC 300
300
1644
KPC 200
200
2000

1800mm DIAMETER
Flat Top
Cover Thickness
Weight
Cover
mm
kg
LGC 200
200
1860
LHC 300
300
2325
LPC 200
200
2900

2100mm DIAMETER
Flat Top
Cover Thickness
Weight
Cover
mm
kg
RGC 200
200
2359
RHC 300
300
2949
RPC 200
200
3700

2400mm DIAMETER
Flat Top
Cover Thickness
Weight
Cover
mm
kg
QGC 200
200
3403
QHC 300
300
4254
QPC 200
200
5250

3000mm DIAMETER
Flat Top
Cover Thickness
Weight
Cover
mm
kg
TGC 300
300
7700
THC 300
300
7600
TPC 300
300
7700


BULLET TYPICAL "TEE"-BASE MANHOLE

arrow  TYPICAL MANHOLE SECTION

Manhole 1500mm-3000mm
rule pipe

arrow  180º TEE BASE CONFIGURATION

Manhole 1500mm-3000mm
rule pipe

BULLET TYPICAL "TEE"-BASE DETAILS

arrow  LONGITUDINAL SECTION

Manhole 1500mm-3000mm
rule pipe

arrow  TRANSVERSE SECTION

Manhole 1500mm-3000mm

Typical 'Tee'-Base Section

'Tee'-Base sections are normally used to provide access to large diameter pipe lines. Generally, slopes are minimal and they have only an inlet and outlet of the same size although smaller inlets may be incorporated in the structure.

They are available in sizes ranging from 600mm to 2400mm diameter concrete pipe. Spigots for 1050mm or 1200mm diameter shafting are cast integral with the base section.

Due to the diverse applications in which they may be utilized, please contact Shaw Precast Solutions for specific information pertaining to your project.

'Tee'-Base
Laid Height
Pipe Diameter (mm)
mm
600
965
750
1130
900
1315
1050
1460
1200
1625
1500
1955
1800
2305
2100
2635
2400
2965
Weights of 'Tee'-Base Units are available on request.


BULLET 
1050-3000mmØ - Typical Internal Drop Manhole

arrow STANDARD MANHOLE DETAILS

Manhole 1500mm-3000mm

BULLET 1050-3000mm DIAMETER DROP MANHOLE
SECTION DETAILS STANDARD DROP MANHOLE

arrow  TYPICAL PLAN

Manhole 1500mm-3000mm

rule pipe

arrow  TYPICAL INTERMEDIATE INTERNAL DROP TOP SECTION

Manhole 1500mm-3000mm

rule pipe

arrow  TYPICAL INTERMEDIATE INTERNAL DROP SECTION

Manhole 1500mm-3000mm

 

Powered By: ssCMS 2.2.0.0