UTILITY BOX 1x1.0m STANDARD

arrow PLAN VIEW WITHOUT COVER
plan view without cover
rule pipe
arrow PLAN VIEW
plan view
rule pipe
arrow SECTION THRU CENTERLINE
section thru centerline
rule pipe

Notes:
- Reinforced For Non-Traffic Loading
- Grade Rings Available For Increased Depth of Bury
- Terminators/Bell End Fittings as Required

rule pipe

Specifications::
- Concrete Minimum Strength: 5000psi [35MPa] at 28 days
- Air Entraining: 5 - 7%
- Steel Reinforcement: #3 [10m] Rebar
- Construction Joint: Sealed with butyl rope or equivalent
- Design for earth dead load only.
- Maximum bury - 5' [1500]

 